Shopping cart is empty
 
English Polski Spanish 
Search For a Manual
 

(e.g. AA-V20EG JVC, ZX-7 Sony )
PayPal 1000+ rating Secure, Encrypted Checkout.
 
Who's Online
There currently are 6043 guests online.
Categories
Information
Featured Product
Home >> CROSSLEE >> G505FLAMESYSTEM5 Owner's Manual
 
 0 item(s) in your cart 

CROSSLEE G505FLAMESYSTEM5
Owner's Manual


Tweet about this product and get $1.00 of store credit for instant use!
  • Download
  • PDF Format
  • Complete manual
  • Language: English
Price: $4.99

Description of CROSSLEE G505FLAMESYSTEM5 Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file after You purchase it.

Owner's Manual ( sometimes referred to as User's Guide or User's Manual ) contains information on how to use Your device. After placing order we'll send You download instructions on Your email address.

The manual is available in languages: English

Not yet ready
You must purchase it first

Customer Reviews
There are currently no product reviews.
Other Reviews
 ADP 4502/5/S WHIRLPOOL Owner's Manual by Phil Atkinson;
It is perfect, exactly what we needed. It's like the paper version but less clutter.
 WM 2105 SIEMENS Owner's Manual by deleteme deleteme;
Received my manual within 24 hours. Very clear scan of the manual I needed. Thanks!
 3362 ALPINE Owner's Manual by Frederic Corneil;
Very clear scan, I recommend it. Definitely a must have for any 3362 owner. Alpine could have written a slightly more complete manual, though. It's already pretty huge, but the unit has so many functions, I feel some more explanation would have been better. Yamaha's manual of their comparable YDSP-1 is a little better in my opinion.
 SX-PC15 TECHNICS Owner's Manual by John Kemp;
Immediate response with excellent service - highly reccommended
 XC1404CB MITSUBISHI Owner's Manual by Michael E Walker;
Correct manual received and of good quality but the contents of the file for the Service Manual for the same monitor is for a 20" TV not the RGB Monitor.

Text excerpt from page 2 (click to view)
The Slimline Turbo is a decorative gas fire which incorporates a horizontal flue that has been designed specifically to be used in applications that do not have a conventional chimney or flue but can be located so that the flue can terminate on an outside wall. The fire is switched `ON� and `OFF� from a push button situated on the right hand top corner of the surround and is controlled by a fully modulating thermoselector thermostat. Once the desired room temperature that has been selected by the control has been reached, the gas input to the appliance is automatically reduced to low. The fire has been constructed to enable it to be installed into applications where the warmth and comfort of an open fire and high radiant heat is required. This appliance is intended for decorative purposes, the coal bed uses ceramic simulated coals to give a realistic appearance and to allow secondary air to be entrained into the bed to ensure clean combustion. An aerated single port steel burner is used running parallel across the front of the fire. A Flame Supervision Device (FSD) is fitted to ensure that should the pilot flame be extinguished for any reason, (including turning off the appliance), the gas supply to the burner is cut off until a full lighting sequence is repeated. A battery operated spark generator is used to ignite an Oxy/pilot sensor (O.D.S) which will cause the appliance to 'shut off' in the event of continued spillage occurring under hazardous or blocked flue conditions. The fire bed consists of ceramic fibre components and coals all of that are removable for cleaning purposes when required. It is important when relaying the coal bed and coals to follow the instructions correctly. TECHNICAL DATA TYPE OF GAS SETTING PRESSURE GAS INPUTS (Gross) G20 only 20 mbar +/- 1 mbar (cold) Max 6.6 kW (22500 Btu/h) Min 2.83 kW (9700 Btu/h) Pilot 0.26 kW (890 Btu/h)

IMPORTANT NOTES This appliance is intended for decorative purposes, it is designed and manufactured to the relevant requirements of EN 509, BSI S.I.T. 8 and BS 5258 Pt 16 : 1991, it is for use on Natural Gas Only. Areas of this appliance will become hot after prolonged running and it is recommended that for the protection of the very young, elderly and infirm a fireguard conforming to BS 6539 or BS 6778 be used. Combustible materials should not be put or left on the hearth nor should the coal bed be used to burn rubbish or other materials. The type of front and fret recommended is shown as Fig 1 in this instruction, it has a perforated fret to allow air to be drawn into the coal bed for combustion and over the controls for cooling purposes. If other fronts and frets are to be used they must have a minimum open area in the fret of 50 sq. cms and 60 sq. cms in the front. Additional purpose built ventilation is not required for this appliance in GB only, for Ireland (IE) ventilation is required with a minimal cross sectional area of 100 sq. cms and should be checked regularly to ensure that it is free from obstruction. It must be fitted in accordance with the rules in force. Care must be taken on the selection of wall coverings within close proximity of the fire as some vinyl and embossed materials may be become discoloured by convected heat. Soft furnishings must be kept clear from the radiant heat of the fire and from impinging the hearth area. The hearth must not be covered by any combustible materials such as carpets etc. This appliance is fitted with an Oxy-pilot, which in the event of the flue being blocked or hazardous conditions exists which causes the appliance to spill products of combustion, will shut `OFF' the gas supply. If when the fire is relit the sequence is repeated the appliance must be turned 'OFF' and not used until expert advice has been obtained. In very strong wind conditions the fan may be heard to increase in speed, this is not detrimental to the operation of the appliance, as the increase is to extract those products that may be prevented leaving the flue by the wind. Exceptionally the fire may shut down and require relighting due to a sustained strong gust. The curing effect of heating the coals will cause an initial odour which, although not harmful, may require additional ventilation until the odour has disappeared. This product uses fuel effect pieces, gaskets and insulation material containing Refractory Ceramic Fibre (RCF), which are manmade vitreous silicate fibres. Excessive exposure to these materials may cause temporary irritation to eyes, skin and respiratory tract, consequently, it makes sense to take care when handling these articles to ensure that the release of dust is kept to a minimum. This fire will run for 4.4 hours on one therm of gas with the gas control on the high setting. -2-

You might also want to buy

$4.99

SX-K700 TECHNICS
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…

$4.99

CJ-V51 PIONEER
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

GRAND PRIX ELECTRONIC 754 BECKER
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

SX-PR602 TECHNICS
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

EV-S1000E SONY
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…

$4.99

GRAND PRIX ELECTRONIC 780 BECKER
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

AG7330 PANASONIC
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

EVO-9850 VOLUME 1 SONY
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…
>
Parse Time: 0.223 - Number of Queries: 136 - Query Time: 0.063